CIRS


RADIATION THERAPY

IMRT Phantoms

IMRT Head & Torso Freepoint Phantom – Model 002H9K

Functions as two phantoms in one. Remove the centre cylinder from the phantom body to simulate head setups. Choose any point dose location within a central diameter of 11.2cm by adjusting the two rotating cylinders. Position lung and bone equivalent rods for assessment of heterogeneity correction. Accomodates ion chambers, diodes, film, MOSFET & TLD.

large_9b88f0446bd6e1cae18268e63c258ce6



IMRT Thorax Phantom – Model 002LFC

One half of the phantom is divided into 12 1cm thick sections to support multiple films. Tissue equivalent interchangeable rod inserts allow heterogeneity corrections. Optional inserts accomodate a variety of detectors.

large_2e97c8c590866b21797f992091aff0eb



IMRT Head and Neck Phantom – Model 002HN

Represents the head anatomy in shape, proportion, structure and density. Supports film and ion chamber measurements.

large_7fc5229a72b6f8b279fc5719a451cce0



IMRT Pelvic 3D Phantom – Model 002PRA

Represents the pelvis anatomy in shape, proportion, structure and density. Supports film and ion chamber measurements.

large_657d9a1570e626fbf7ee802c74582380



Electron Density Phantoms

CBCT Electron Density and Image Quality Phantom – Model 062QA

This phantom has two functions – electron density calibration, and image quality assessment of CBCT systems. It has several components:
Head and Abdomen Electron Density Phantoms with 8 different tissue equivalent inserts able to be positioned at 17 different locations.

large_8466acc68cc2f73a0e8a3804b334a842

CBCT Image Quality Head Phantom has four layers, as below:

Spatial Resolution Layer to evaluate spatial resolution of IGRT systems, with line pair patterns from 1 lp/cm to 16 lp/cm.
Untitled1


CT Number Linearity & Slice Thickness Layer to determine contrast to noise ratio, HU number accuracy, slice thickness using 6 different rods.
062QA_CTSlice_PHO

Low Contrast Layer to assess the CBCT systems ability to detect small differences in contrast and comprises 3 sets of low contrast rods with progressively different linear attenuations, also provides input for calculation of Point Spread Function and MTF.
062QA_LowContrast_PHO

Uniformity Layer to measure CBCT ability to produce uniform images across the FOV using this highly homogeneous slab.

thumb_5f1825e30302fa50ca955d8a901b8a1f
CBCT Electron Density Phantom – Model 062A

This phantom is designed for CBCT systems (but can be used for multi-slice CT) with additional material and ability for off CAX measurements, for correlation of CT number to electron density calibration in volumetric imaging. Also accommodates ion chamber.

large_b1c74421d1972d1d4d83a4f8d00d7509


Electron Density Phantom – Model 062

Establishes CT number to electron density calibration. Consists of Head and Abdomen configurations with 8 different tissue equivalent inserts able to be positioned at 17 different locations.


large_8466acc68cc2f73a0e8a3804b334a842


General Radiation Therapy QA Tools

Plastic Water – Model PW

Calibrate photon and electron beams using the unbreakable Original PW, for energies 150keV to 100MeV. Available in depths from 1mm to 7cm. Other versions available for low energy brachytherapy sources or CT dose verification, plus diagnostic to radiotherapy energy ranges.

Untitled3

Iso Cube Daily QA Phantom – Model 023

Daily system check of radiation with light field alignment, kV/MV imager coincidence, laser alignment, light field size verification, ODI & couch height accuracy. Includes off-centre target for verifying couch movements. Shown with alignment platform.

Untitled2

Water Equivalent Mini Phantom – Model 670 & 670S

Using a standard ion chamber on the stand measure head-scatter factors without side scatter contribution.

large_0b8850f95195147ea64b059853bbc31a


Cube 20 Phantom – Model 009

Position chamber, diode, MOSFET detectors at isocentre of the cube, with ability to make small adjustments to detector positioning, for patient QA and beam constancy checks. Also accomodates film.

large_e4989293dded6a34d0edafa25013e13d

ATOM Dosimetry Verification Phantoms

Models 701 - 706

Anthropomorphic whole-body cross-sectional dosimetry phantoms to investigate organ dose, whole body effective dose or delivery QA of radiation.

large_0e74277fcb0216de7574a5517f51f7b4



Gating Phantoms


Dynamic Thorax Phantom – Model 008A

One half of Platform also available separately.



Diagnostic

Diagnostic CT Phantoms

Fluoroscopy/X-ray Phantoms

Multi-Modality

ULTRASOUND

MAMMOGRAPHY